{"product_id":"h0011800410p-genuine-haier-air-conditioner-outdoor-unit-main-pcb","title":"H0011800410P Genuine Outdoor Unit Main PCB Control Board for Haier Split System Air Conditioners 1U71SA1ERA","description":"\u003cp\u003eInside the outdoor unit of a Haier split system sits the main control board, and H0011800410P is the genuine replacement. It's on file for the 1U71SA1ERA outdoor unit. Check that the model on the outdoor unit's rating label matches, as boards differ between Haier outdoor units, and quote the indoor unit model too if you need help confirming fit.\u003c\/p\u003e\n\u003ch2\u003eHaier outdoor unit not running\u003c\/h2\u003e\n\u003cp\u003eThe outdoor PCB runs the outdoor half of the system. It talks to the indoor unit, starts and controls the compressor and outdoor fan, and reads the temperature sensors. When it fails, the indoor unit may blow air that never gets cold or warm, show an error code, or the outdoor unit may not start at all. Lightning, power surges, insects nesting in the casing and moisture are common causes of board damage. A technician should check the supply, wiring and communication link before condemning the board, since those faults can look identical.\u003c\/p\u003e\n\u003ch2\u003ePart details\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Haier part H0011800410P\u003c\/li\u003e\n\u003cli\u003eMain control PCB for the outdoor unit\u003c\/li\u003e\n\u003cli\u003eOn file for the Haier 1U71SA1ERA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWho should fit an outdoor PCB\u003c\/h2\u003e\n\u003cp\u003eSplit systems are hard-wired, so this board must be fitted by a licensed electrician or licensed air conditioning technician. Isolate the power at the outdoor isolator and the switchboard, then allow time for the capacitors on the board to discharge before work starts. Record all connections and sensor plugs, fit the new board and test both heating and cooling once it's running.\u003c\/p\u003e\n\u003ch2\u003eQuestions about this part\u003c\/h2\u003e\n\u003ch3\u003eCan I fit this board myself?\u003c\/h3\u003e\u003cp\u003eNo. Air conditioners are hard-wired and the outdoor board carries high voltages, including stored charge after the power is off. Under Australian rules this work needs a licensed electrician or licensed air conditioning technician.\u003c\/p\u003e","brand":"Haier","offers":[{"title":"Default Title","offer_id":44551029817422,"sku":"H0011800410P","price":325.71,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/3489\/7998\/files\/h0011800410p-genuine-haier-air-conditioner-outdoor-unit-main-pcb.jpg?v=1792026350","url":"https:\/\/partsshop.com.au\/products\/h0011800410p-genuine-haier-air-conditioner-outdoor-unit-main-pcb","provider":"My Store","version":"1.0","type":"link"}